Related Experiment Video
Updated: May 28, 2025

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Downsizing Overlap Stenting for Bronchial Anastomotic Dehiscence Size Mismatch in Lung Transplant
Bryan F Vaca-Cartagena1, Rodrigo Funes-Ferrada1, Alejandra Yu Lee-Mateus1
1Division of Pulmonary Allergy, and Sleep Medicine, Mayo Clinic Jacksonville Florida USA.
Abstract:
Bronchial dehiscence is a known complication following lung transplantation. In cases involving extensive airway necrosis and air leaks, bronchoscopic placement of self-expanding metallic stents provides an effective and safe management strategy. These stents facilitate granulation and tissue reepithelialization. We present a case of bronchial anastomotic dehiscence size mismatch after a lung transplant. This complication was successfully managed using three stents placed via a telescoping technique with flexible bronchoscopy.