Related Experiment Video
Updated: Jul 12, 2026

Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes
Published on: March 3, 2023
Three-Month Outcomes of SMILE Pro with the VISUMAX 800 for Myopic Astigmatism in a Large Population
Hong Son Cung1,2, Lan Huong Thi Tran1,2, Thanh Ngoc Tran1,2
1Vietnam National Eye Hospital, Ha Noi, Vietnam.
Purpose:
To report the visual and refractive outcomes of small-incision lenticule extraction (SMILE) Pro using a 2 MHz femtosecond laser for myopic astigmatism in a large population of Vietnamese patients.
Methods:
This was a retrospective clinical study of subjects that underwent keratorefractive lenticule extraction (KLEx) with the VISUMAX 800 at Hong Son Eye Hospital (Ha Noi, Vietnam) between June 2023 and October 2023. Primary outcome measures of monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and refraction, including vector analysis, were evaluated at 3-months postoperatively. Secondary outcome measures of intraoperative and postoperative complications were also recorded.
Results:
A total of 765 eyes from 389 patients (60.66% women, mean age of 23.54±5.20 years) were analyzed 3 months after surgery. The mean preoperative spherical equivalent refraction was -5.98±2.26 D. The postoperative spherical equivalent refraction was within ±0.50 D of the intended target in 81% and within ±1.00 D in 97% of eyes. The mean spherical equivalent refraction was -0.11±0.45 D. UDVA was 20/25 or better in 92% and 20/32 or better in 97% of eyes. The mean postoperative UDVA and CDVA values were 0.05±0.09 and 0.00±0.02 logMAR, respectively. There was no change in CDVA in 99% of eyes. Efficacy index was 0.92, and safety index was 1.00. One eye (0.13%) had a suction loss, which resulted in a lenticule remnant. No other complications were reported during surgery or the postoperative follow-up period.
Conclusion:
The current study, carried out on a large cohort of Asian patients, showed SMILE Pro with the VISUMAX 800 was safe and effective for treating myopic astigmatism.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment