Related Experiment Video
Updated: May 28, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Radon in schools of Montenegro
Perko Vukotic1, Ranko Zekic2, Nikola Svrkota2
1Montenegrin Academy of Sciences and Arts, R. Stijovica, Podgorica, Montenegro.
Abstract:
During the school year, radon (222Rn) was continuously measured with passive detectors in all public schools in Montenegro-345 primary and 47 secondary schools. Measurements were taken in all ground-floor classrooms and offices (2336 rooms in total), as well as in 182 first-floor rooms across 91 schools. On the first floor, the arithmetic mean (AM) of radon concentrations was 100 Bq/m3, and the median (MED) was 65 Bq/m3, with only five schools having rooms where radon levels exceeded 300 Bq/m3. On the ground floor of all 392 schools, the AM was 276 Bq/m3, and the MED was 146 Bq/m3. In 188 schools, some rooms had radon levels above 300 Bq/m3, and in 43 schools, certain rooms exceeded 1000 Bq/m3. An assessment of the effective annual doses from radon inhalation for pupils was also conducted. On average, the dose was 0.66 mSv per school year, although in some classrooms it reached up to 11 mSv.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radioactive Decay and Radiometric Dating
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Isotopes and Radioisotopes
An isotope containing...