Related Experiment Video
Updated: May 28, 2025

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Comparison of Two Coronary Anastomosis Techniques in Terms of Flow Rate in Porcine Hearts
Safa Gode1, Mucahit Polat1, Elif Guneysu1
1Department of Cardiovascular Surgery, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Introduction:
The quality of coronary anastomoses is one of the important parameters that may affect graft patency in coronary artery bypass grafting patients. Therefore, we compared two different anastomotic techniques to improve graft flow and patency rates.
Methods:
This study was conducted by performing two different fashions of anastomosis with a human saphenous vein graft on 24 various coronary segments of five postmortem porcine hearts. Each arteriotomy was used for both anastomotic techniques. In the first method, epicardial fat tissue around the coronary artery was involved to the saphenous vein anastomosis line (coronary wall and epicardial fat tissue [CWE] technique). In the second method, the saphenous vein graft was sutured to the coronary wall only, without involving epicardial fat tissue (only coronary wall [OCW] technique).The time it tookfor 30 cc of 0.9% isotonic saline solution to pass through the anastomosis in a free-flow fashion by gravity was measured following each technique. Additionally, the anastomotic areas in mm2 were measured and compared between the two techniques.
Results:
The mean flow time for the CWE technique was 77.5 ± 21.4 seconds, whereas for the OCW technique, it was 87.2 ± 19.5 seconds (P<0.001). The flow rates were 23.2 ml/min and 20.6 ml/min, respectively. The anastomotic area was 3.947 mm2 for the CWE technique and 1.430 mm2 for the OCW technique.
Conclusion:
When the sutures penetrate both the epicardial fat tissue and the coronary artery wall simultaneously, a larger anastomosis area can be created. Consequently, potentially better graft flow and hemodynamic performance could be achieved.