Related Experiment Video
Updated: Jul 14, 2026

Turbidimetry on Human Washed Platelets: The Effect of the Pannexin1-inhibitor Brilliant Blue FCF on Collagen-induced Aggregation
Published on: April 6, 2017
A rapid whole-blood adenosine triphosphate secretion test can be used to exclude platelet-dense granule deficiency
Minka Zivkovic1, Roger E G Schutgens2, Vossa van der Vegte1
1Center for Benign Haematology, Thrombosis and Haemostasis, Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands; Circulatory Health Research Center, University Medical Center Utrecht, Utrecht, the Netherlands.
Background:
Delta storage pool disease (δ-SPD) is a rare platelet function disorder (PFD) characterized by a deficiency of dense granules or defective granule secretion, leading to bleeding diathesis. Diagnostics of δ-SPD are difficult and lack standardization, leading to underestimation of its prevalence. Current diagnostic methods are based on granule content assays or lumi-aggregometry, which have limited availability. Therefore, there is an unmet need for a rapid, accessible test for δ-SPD.
Objectives:
To evaluate the diagnostic value of a rapid whole-blood adenosine triphosphate (ATP) secretion test for δ-SPD.
Methods:
ATP secretion after PAR-1 activating peptide (PAR-1 AP; TRAP-6) stimulation was assessed in whole blood using luminescence in 50 healthy controls, 22 patients with a suspected PFD other than storage pool disease (non-SPD) and 25 patients with δ-SPD and corrected for platelet count. Diagnostic value of the test was determined with C-statistics, sensitivity, specificity, likelihood ratios (LLRs), and predictive values (PVs).
Results:
PAR-1 AP mediated ATP secretion in the rapid test was lower in δ-SPD than in healthy controls and non-SPD patients (P < .0001). The rapid test was able to discriminate between δ-SPD and non-SPD patients (C-statistic 0.88; 95% CI, 0.78-0.98). At a cutoff value of the highest value of the δ-SPD group, the sensitivity was 100% and the specificity was 64%. This cutoff value corresponded with a positive LLR of 2.75, an optimal negative LLR of 0.00, positive PV of 76%, and negative PV of 100%.
Conclusion:
A whole-blood ATP secretion test can be used to exclude ẟ-SPD in patients presenting with a primary hemostasis defect.
More Related Videos
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Serum Laboratory Studies, Stool Test, Breath Test
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Acute Coronary Syndrome III: Diagnostic Studies

