Aluminum oxide ceramic ossicular replacement prosthesis.

E Yamamoto

    The Annals of Otology, Rhinology, and Laryngology
    |March 1, 1985
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Self-Reconstruction of Order Parameter in Spin-Triplet Superconductor UTe_{2}.

    Physical review letters·2025
    Same author

    Effect of uranium deficiency on normal and superconducting properties in unconventional superconductor UTe<sub>2</sub>.

    Journal of physics. Condensed matter : an Institute of Physics journal·2022
    Same author

    Erratum: Azimuthal Anisotropy of K_{S}^{0} and Λ+Λ[over ¯] Production at Midrapidity from Au+Au Collisions at sqrt[s]_{NN}=130  GeV [Phys. Rev. Lett. 89, 132301 (2002)].

    Physical review letters·2021
    Same author

    Erratum: Azimuthal Anisotropy at the Relativistic Heavy Ion Collider: The First and Fourth Harmonics [Phys. Rev. Lett. 92, 062301 (2004)].

    Physical review letters·2021
    Same author

    Efficiency of genomic selection for breeding population design and phenotype prediction in tomato.

    Heredity·2016
    Same author

    Direct observation of lattice symmetry breaking at the hidden-order transition in URu2Si2.

    Nature communications·2014
    Same journal

    Laryngeal Injuries Following General Endotracheal Anesthesia: A Case Series.

    The Annals of otology, rhinology, and laryngology·2026
    Same journal

    Clinical and Voice Outcome Differences in Vocal Cord Cysts with and Without Sulcus Vocalis: Insights From a Tertiary Center in Saudi Arabia.

    The Annals of otology, rhinology, and laryngology·2026
    Same journal

    Bioabsorbable Stenting in a Case of Severe Pediatric Posterior Glottic Stenosis.

    The Annals of otology, rhinology, and laryngology·2026
    Same journal

    Efficacy and Safety of Finafloxacin Otic Suspension, 0.3% for the Treatment of Acute Otitis Externa: Results from two Phase III Randomized Clinical Studies.

    The Annals of otology, rhinology, and laryngology·2026
    Same journal

    Evaluation Of the Expression Levels Of SerpinB3/B4/B10, Interleukin-17 As Biomarkers For Chronic Rhinosinusitis With Nasal Polyps.

    The Annals of otology, rhinology, and laryngology·2026
    Same journal

    Correlation of Patient-Reported Symptoms With Rhinogram Features Beyond Simple Airway Resistance.

    The Annals of otology, rhinology, and laryngology·2026
    See all related articles

    Two novel aluminum oxide ceramic ossicular replacement prostheses (CORP-P and CORP-T) were designed for ossicular reconstruction. These ceramic implants offer unique head shapes for fascia graft contact and radiopacity for post-operative X-ray confirmation.

    Area of Science:

    • Biomaterials Science
    • Otolaryngology
    • Medical Device Design

    Background:

    • Ossicular reconstruction is a surgical procedure to restore hearing by replacing or repairing damaged middle ear bones.
    • Current ossicular replacement prostheses have limitations in terms of biocompatibility, stability, and intraoperative handling.
    • The development of advanced ceramic materials offers potential for improved prosthetic devices.

    Purpose of the Study:

    • To design and introduce two novel prototypes of ceramic ossicular replacement prostheses (CORP-P and CORP-T) for ossicular reconstruction.
    • To highlight the unique design features of these prostheses, including head shape and radiopacity.
    • To evaluate the suitability of aluminum oxide ceramics for middle ear implantation.

    Main Methods:

    Related Experiment Videos

  • Design and fabrication of two distinct columella prototypes using aluminum oxide ceramics.
  • CORP-P (partial) designed to fit the stapes head.
  • CORP-T (total) designed for placement on the stapes footplate.
  • Main Results:

    • The designed prostheses, CORP-P and CORP-T, are made from aluminum oxide ceramic.
    • CORP-P and CORP-T feature a unique head shape for enhanced contact with fascia grafts.
    • The implants possess radiopacity, enabling visualization via X-ray for positional verification post-surgery.

    Conclusions:

    • The newly designed ceramic ossicular replacement prostheses (CORP-P and CORP-T) present innovative solutions for ossicular reconstruction.
    • The specific design features address key aspects of prosthetic implantation, including graft interface and radiographic assessment.
    • Aluminum oxide ceramics demonstrate promise as a material for advanced middle ear prosthetics.