Related Experiment Video
Updated: May 28, 2025

08:15
Data Communication Based on MQTT in a Polymer Extrusion Process
Published on: July 15, 2022
3.4K
Robust Access Control for Secure IoT Outsourcing with Leakage Resilience
1Computer Science Department, College of Computer Sciences & Information Technology, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
Sensors (Basel, Switzerland)
|February 13, 2025
Summary
This study introduces a secure access control for the Internet of Things (IoT) using Attribute-Based Encryption (ABE). It enhances data privacy and security for resource-constrained IoT devices by offloading decryption to the cloud.
Area of Science:
- Computer Science
- Cybersecurity
- Cryptography
Background:
- The Internet of Things (IoT) enables widespread connectivity but faces significant security and privacy challenges due to device resource constraints.
- Outsourced data security in IoT environments is a critical concern, necessitating robust access control mechanisms.
Purpose of the Study:
- To propose a novel, leakage-resilient access control scheme for IoT data.
- To enhance security and privacy for resource-constrained IoT devices through efficient data handling.
Main Methods:
- Developed an Attribute-Based Encryption (ABE) scheme incorporating partial decryption outsourcing.
- Offloaded intensive decryption computations to cloud servers to minimize IoT device overhead.
- Incorporated resilience against master secret key leakage and side-channel attacks.
Main Results:
- The proposed scheme demonstrates robustness under standard cryptographic assumptions.
- Significant improvements in decryption efficiency, scalability, and computational performance were observed.
- The scheme effectively addresses security and privacy challenges in outsourced IoT data.
Conclusions:
- The developed ABE scheme provides a scalable, efficient, and secure access control framework for IoT.
- This solution is well-suited for real-world IoT applications in smart healthcare, industrial IoT, and smart cities.
Keywords:
Internet of Things (IoT)access controlattribute-based encryption (ABE)leakage resiliencemaster secret key protectionoutsourced decryptionsecure data outsourcingside-channel attacksMore Related Videos
Related Concept Videos
Line Protection with Impedance Relays
64
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
64
Legal Guidelines for Documentation
1.3K
The legal guidelines for nursing documentation are essential for ensuring accurate, professional, and ethical recording of patient care. The guidelines are discussed here:
1.3K
Ethical Standards I
772
The American Nurses Association (ANA) created and implemented the first nationally accepted Code of Ethics for Nurses with Interpretive Statements. The Code of Ethics is a living document regularly updated by the ANA and establishes an ethical standard that is non-negotiable for nurses in all roles and settings.
The Code of Ethics provisions outline the nurse's duty to the patient, the healthcare team, the profession, and society. The Code's fundamental principles include advocacy,...
The Code of Ethics provisions outline the nurse's duty to the patient, the healthcare team, the profession, and society. The Code's fundamental principles include advocacy,...
772
Radial System Protection
88
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
88
Overcurrent Relays
66
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
66
Control Systems
1.0K
Control systems are everywhere in contemporary society, influencing diverse applications from aerospace to automated manufacturing. These systems can be found naturally within biological processes, such as blood sugar regulation and heart rate adjustment in response to stress, as well as in man-made systems like elevators and automated vehicles. A control system is essentially a network of subsystems and processes that collaboratively convert specific inputs into desired outputs.
At the heart...
At the heart...
1.0K

