Related Experiment Video
Updated: May 28, 2025

Psychophysically-anchored, Robust Thresholding in Studying Pain-related Lateralization of Oscillatory Prestimulus Activity
Published on: January 21, 2017
Estimation of Pressure Pain in the Lower Limbs Using Electrodermal Activity, Tissue Oxygen Saturation, and Heart Rate
Youngho Kim1, Seonggeon Pyo1, Seunghee Lee1
1Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
Abstract:
Quantification of pain or discomfort induced by pressure is essential for understanding human responses to physical stimuli and improving user interfaces. Pain research has been conducted to investigate physiological signals associated with discomfort and pain perception. This study analyzed changes in electrodermal activity (EDA), tissue oxygen saturation (StO2), heart rate variability (HRV), and Visual Analog Scale (VAS) under pressures of 10, 20, and 30 kPa applied for 3 min to the thigh, knee, and calf in a seated position. Twenty participants were tested, and relationships between biosignals, pressure intensity, and pain levels were evaluated using Friedman tests and post-hoc analyses. Multiple linear regression models were used to predict VAS and pressure, and five machine learning models (SVM, Logistic Regression, Random Forest, MLP, KNN) were applied to classify pain levels (no pain: VAS 0, low: VAS 1-3, moderate: VAS 4-6, high: VAS 7-10) and pressure intensity. The results showed that higher pressure intensity and pain levels affected sympathetic nervous system responses and tissue oxygen saturation. Most EDA features and StO2 significantly changed according to pressure intensity and pain levels, while NN interval and HF among HRV features showed significant differences based on pressure intensity or pain level. Regression analysis combining biosignal features achieved a maximum R2 of 0.668 in predicting VAS and pressure intensity. The four-level classification model reached an accuracy of 88.2% for pain levels and 81.3% for pressure intensity. These results demonstrated the potential of EDA, StO2, HRV signals, and combinations of biosignal features for pain quantification and prediction.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Assessment Sites
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

