Detailed Modeling of Surface-Plasmon Resonance Spectrometer Response for Accurate Correction
Ricardo David Araguillin-López1,2, Angel Dickerson Méndez-Cevallos2, César Costa-Vera2
1Departamento de Automatización y Control Industrial, Escuela Politécnica Nacional, Quito 170525, Ecuador.
Abstract:
This work identifies and models the inline devices in an experimental surface-plasmon resonance spectroscopy setup to determine the system's transfer function. This allows for the comparison of theoretical and experimental responses and the analysis of the dynamics of the components of an analyte placed on the sensor at the nanometer scale. The transfer functions of individual components, including the light source, polarizers, spectrometer, optical fibers, and the SPR sensor, were determined experimentally and theoretically. The theoretical model employed Planck's law for the light source, manufacturer specifications for some components, and experimental characterization for others, such as the polarizers and optical fibers. The SPR sensor was modeled using characteristic matrix theory, incorporating the optical constants of the prism, gold film, chromium adhesive layer, and analyte. The combined transfer functions created a comprehensive model of the entire experimental system. This model successfully reproduced the experimental SPR spectrum with a similarity greater than 95%. The system's operational range was also extended, constrained by the signal-to-noise ratio at the spectrum's edges. The detailed model allows for the accurate correction of the measured spectra, which will be essential for the further analysis of nanosuspensions and molecules dissolved in liquids.
More Related Videos
08:01Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
Published on: November 21, 2019
06:12Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
Published on: March 17, 2023
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
UV–Vis Spectrometers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...