The Impact of Contrast Media on Lumbar Spine Bone Mineral Density Measured by Quantitative Computed Tomography
Lahari R Shetty1, Kaushik Nayak1, Priyanka1
1Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India.
Background:
Osteoporosis is a bone disease caused by decrease in bone mineral density (BMD). Quantitative computed tomography (QCT) has proven to be an effective tool to measure the BMD of the lumbar spine. Therefore, the objective of the study is to investigate the impact of intravenous contrast media (CM) on BMD of lumbar spine measured by QCT.
Methods:
This is a prospective study and included a total of 141 patients (females: 71, males: 70) referred for contrast enhanced computed tomography (CECT) abdomen. First, the plain scan of abdomen was done. Contrast media was injected intravenously followed by acquisition of arterial and portovenous phase (PV) of abdomen. Plain, arterial and PV phases axial CT images were loaded on Philips BMD analysis application. A circular region of interest (ROI) measuring 30-40 mm2 was placed at all five lumbar vertebrae (L1-L5) and value of BMD was obtained in mg/cm3.
Results:
Paired t-test was used to compare BMD in plain, arterial and PV phase. There was significant difference (p <0.05) in BMD (L1-L5) between plain (110.86±36.61 mg/cm3), arterial (117.04±37.95 mg/cm3) and PV phase (127.52±40.9 mg/cm3). The study also noted significant difference between males and females in BMD of lumbar spine (L1-L5) for plain and CECT abdomen (p <0.05).
Conclusion:
The BMD was highest for PV phase of the CECT abdomen. Therefore, the study concludes that BMD values are highly influenced by intravenous contrast media injections.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...