Enhanced heart sound anomaly detection via WCOS: a semi-supervised framework integrating wavelet, autoencoder and SVM
Peipei Zeng1, Shuimiao Kang2,3, Fan Fan4
1Civil Aviation University of China Engineering Technology Training Center, Civil Aviation University of China, Tianjin, China.
Abstract:
Anomaly detection is a typical binary classification problem under the condition of unbalanced samples, which has been widely used in various fields of data mining. For example, it can help detect heart murmurs when the heart is structurally abnormal, to tell if a newborn has congenital heart disease. Due to the low time and high efficiency, most work focuses on the semi- supervised anomaly detection method. However, the anomaly detection effect of this method is not high because of massive data with uneven samples and different noise. To improve the accuracy of anomaly detection under unbalanced sample conditions, we propose a new semi-supervised anomaly detection method (WCOS) based on semi-supervised clustering, which combines wavelet reconstruction, convolutional autoencoder, and one classification support vector machine. In this way, we can not only distinguish a small proportion of abnormal heart sounds in the huge data scale but also filter the noise through the noise reduction network, thus significantly improving the detection accuracy. In addition, we evaluated our method using real datasets. When the noise of sigma = 0.5, the AUC standard deviation of the WR-CAE-OCSVM is 19.2, 54.1, and 29.8% lower than that of WR-OCSVM, CAE-OCSVM and OCSVM, respectively. The results confirmed the higher accuracy of anomaly detection in WCOS compared to other state-of-the-art methods.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.