Related Experiment Video
Updated: May 28, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Improved active current limiting control for flexible DC power grid to consider the effects of selective and higher
Xiaohua Qin1, Junjie Hou2, Yanfang Fan3
1School of Electrical Engineering, Xinjiang University, Urumqi, China.
Abstract:
The current limiting control strategy of modular multilevel converters in flexible DC power grids can effectively reduce the requirements for line protection speed and the breaking capacity of DC circuit breakers (DCCB). However, it can easily lead to the interruption of power transmission at non-fault terminals and expanding the scope of the fault impact. Secondly, it did not consider the severity of matching faults, which may lead to excessive suppression of fault currents and reduce the sensitivity of the protection system. Therefore, this paper proposes an active current limiting control (ACLC) strategy with fault identification capability to further improve its selectivity and adaptability. Firstly, the starting element in the ACLC selectively identify fault areas based on the difference in the slope of the first backward traveling wave (TW) of the current. Secondly, a current limiting coefficient is constructed based on the slope of the first backward TW of current to achieve fault current limiting. On this basis, setting amplitude control to improve the adaptability of ACLC to fault resistance. Finally, a complete fault handling scheme was proposed, including ACLC, fault identification and fault isolation. The simulation results show that the proposed ACLC strategy is selective while reducing the technical requirements of DCCB. In addition, the adaptability of ACLC to fault resistance has also been improved.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Directional Relays
Power System Three-Phase Short Circuits
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Differential Relays