Introduction:
Periprosthetic joint infection (PJI) may result from pathogen-to-patient transmission within the environment. High-touch surfaces (HTS) areas near the operative field from previous studies had been identified as the least likely to be thoroughly cleaned between operative cases and were utilized for this study. The purpose of this study was to assess the impact of a handheld ultraviolet-c (UV-C) light-emitting diode (LED) disinfection device on the decontamination of HTS in the operating room.
Methods:
This prospective study was conducted between 03/02/2021 and 04/20/2021. Tryptic soy agar contact plates were used to determine the bacterial load of the selected surfaces before the initiation of the case, after the case was complete, before manual cleaning, and after disinfection of the LED device. The plates were then incubated for 48 hours at 36º +/-1° C. Colony forming units (CFU) were recorded 48 hours after incubation. Mean, median, and range of CFU were recorded.
Results:
Average CFU per surface before and after the surgical case were 14.1 (range 0-200) and 13.5 (range 0-200) respectively, these were not significantly different (P = 0.9397). Manual cleaning reduced average CFU by 74% to 3.35 (range 0-200) per surface (P = 0.0162). Disinfection with the handheld LED unit further reduced the average CFU by 92% to 0.28 (range 0-4) per surface (P < 0.0001).
Conclusions:
A handheld UV-C LED disinfection device may decrease environmental contamination near the operative field in HTS areas. Further research is warranted with this technology to determine if this correlates with a decrease in PJI.
More Related Videos
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...