Ridge Augmentation Using a Self-Retaining Block Bone Material in Damaged Extraction Sockets: A Multi-Centre
Shinyoung Park1, Joo-Yeon Lee1, Jin-Young Park1
1Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, Korea.
Aim:
To compare the dimensional stability of a self-retaining synthetic block bone (srBB) and synthetic bone particles (SBP) for alveolar ridge augmentation (ARA) in damaged extraction sockets.
Materials And Methods:
ARA was randomly performed in two centres on 57 participants presenting damaged extraction socket in a non-molar tooth: (i) srBB and collagen membrane (srBB group, n = 29) or (ii) SBP and collagen membrane (SBP group, n = 28). Cone beam computed tomography (CBCT) was performed immediately after ARP (baseline, T0) and at 6 months (T1). T0 and T1 CBCTs were superimposed, and horizontal widths (H0-H5), vertical heights and volume changes were assessed using t-test.
Results:
Due to wound dehiscence, srBB was removed in 10 patients. The change in horizontal width at the most coronal level (H0) was significantly lower for srBB compared to SBP (srBB: 0.8 ± 1.0 mm; SBP: 1.9 ± 2.2 mm, p < 0.05). Significantly less volume decrease was seen at the bucco-coronal level for srBB (srBB: 3.2 ± 0.6 mm3; SBP: 10.4 ± 2.3 mm3, p < 0.05).
Conclusion:
Compared to synthetic bone particles, synthetic bone blocks have the potential to more effectively augment and maintain the coronal horizontal dimension and width of damaged extraction sockets for up to 6 months. However, this advantage is offset by their relatively high rates of early wound dehiscence.
Trial Registration:
Korean Clinical Research information service (CRIS) (KCT0005462).