Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Assessing proton plans with 3 different beam lines vs photon plans for early-stage lung cancer
Tara Gray1, Chieh-Wen Liu1, Anna Maria Kolano2
1Department of Radiation Oncology, Cleveland Clinic Foundation, Cleveland, OH, USA.
Abstract:
To compare proton plans (IMPT) to VMAT plans and intercompare proton plans using 3 different spot sizes with robustness: cyclotron-generated proton beams (CPB) (σ: 2.7-7.0 mm), linear accelerator proton beams (LPB) (σ: 2.9-5.5 mm), and linear accelerator proton mini beams (LPMB) (σ: 0.9-3.9 mm) for the treatment of early-stage lung cancer. Twenty-two lesions from a total of twenty patients with early-stage lung cancer, originally treated with SBRT, were replanned using CPBs, LPBs, LPMBs, and VMAT using the same treatment planning system and dose calculation algorithm. The average intensity projected CTs (AIP-CT) were used for planning and 3D robust optimization was used for all proton plans. Conformity index (CI), homogeneity index (HI), R50, lung V20 Gy, and mean lung dose were compared among all proton plan types and with VMAT plans. Set-up uncertainties of ±5 mm and ±3.5% range uncertainty were included in the IMPT robust optimization and evaluation, using V100%Rx > 98% of the ITV. The Wilcoxon signed-rank test was used to evaluate statistical differences between VMAT plans and all proton plan types. When compared to VMAT plans, all proton plans generally show improvement in CI, HI, Lung V20 Gy, Mean lung dose, and R50. The LPMB plans showed the most improvement from VMAT plans. Comparison between CPB and linear accelerator proton plans showed statistical significance (p < 0.05). R50 and mean lung dose for the CPB, LPB and LPMB plans were 3.6 ± 0.9, 3.1 ± 0.8 and 2.6 ± 0.6; 2.2 ± 1.1 Gy, 1.9 ± 1 Gy and 1.6 ± 0.9 Gy, respectively (p < 0.05). The mean R50 and mean lung dose from the VMAT plans were 4.1 ± 0.4 and 3.8 ± 2 Gy, respectively. The V20 Gy (%) of lung and mean lung dose were improved across all proton plans when compared with those of VMAT plans. When evaluated for robustness in the worst-case scenario at V100%Rx of the ITV > 98%, average ITV coverage of 98.6 ± 0.3%, 98.6 ± 0.6%, and 98.9 ± 0.6% were achieved for CPB plans, LPB plans, and LPMB plans, respectively. With decreased spot size, the LPB and LPMB plans are excellent alternatives to VMAT and cyclotron-generated proton plans with reduced dose to normal tissue and improved plan quality for early-stage lung cancer treatments.