Anisotropy visualisation from X-ray diffraction of biological apatite in mixed phase calcified tissue samples
Robert Scott1, Iain D Lyburn2,3,4, Eleanor Cornford3
1Cranfield Forensic Institute, Cranfield University, Bedford, UK. robert.scott@cranfield.ac.uk.
Abstract:
X-ray diffraction is widely used to characterise the mineral component of calcified tissue. Broadening of the diffraction peaks yields valuable information on the size of coherently diffracting domains, sometimes loosely described as crystallite size or crystallinity. These domains are markedly anisotropic, hence a single number describing their size is misleading. We present a novel variation on a method for visualising crystallographic anisotropy in X-ray diffraction data. This provides an intuitively interpretable depiction of crystalline domain size and anisotropy. The new method involves creating a polar plot of calculated domain thickness for peaks in a diffractogram versus crystallographic direction. Points with the least error are emphasised. Anisotropic domain dimensions are calculated by refining an ellipsoidal model in a whole pattern fit. These dimensions are then used to overlay an ellipse on the peak broadening plot. This is illustrated by application of the method to calcifications in breast tissue with suspected cancer, which frequently contain whitlockite as well as nanocrystalline apatite. Like most biogenic apatite, this exhibits markedly anisotropic peak broadening. The nature of this anisotropy offers potentially useful information on normal function and pathology of calcified tissue and is a frequently neglected crystallographic feature of these materials.
More Related Videos
08:51Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
14:55Analysis of Minerals Produced by hFOB 1.19 and Saos-2 Cells Using Transmission Electron Microscopy with Energy Dispersive X-ray Microanalysis
Published on: June 24, 2018
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...