Related Experiment Video
Updated: May 28, 2025

Experimental System of Solar Adsorption Refrigeration with Concentrated Collector
Published on: October 18, 2017
New approach to improve COP and heat recovery in transcritical CO2 refrigeration system for milk processing
Prosenjit Singha1, Chayan Das2, Mani Sankar Dasgupta2
1Department of Mechanical Engineering, BITS Pilani, Pilani, 333031, India. prosenjit.singha@pilani.bits-pilani.ac.in.
Abstract:
In hot climates, subcooling or after-cooling is an effective method to enhance the coefficient of performance (COP) of CO2 transcritical refrigeration system. This study investigates improvement of two contemporary subcooling arrangements: Integrated mechanical subcooling (IMS) and dedicated mechanical subcooling (DMS) and evaporative cooling arrangement to gascooler by introduction of gravity-fed evaporator in a dual evaporator parallel compression system suitable for milk processing. Using location-specific average meteorological data, the performance of the proposed systems is evaluated for Pune, India. Comparative analysis is conducted against a baseline transcritical CO2 system with flash gas bypass but lacking any subcooling arrangement. A considerable improvement in COP is observed when subcooling is combined with parallel compression. Incorporation of evaporative cooling with parallel compression yields 62.3% improvement in COP over the flash gas bypass system. However, heat recovery potential is considerably reduced by adopting evaporative cooling. Additionally, the study quantifies a potential reduction in water consumption of 45.6% over a system using flash gas bypass with an indirect evaporative cooling arrangement, and a reduction of 34.3% over a system employing parallel compression with a split gas cooler indirect evaporative cooling arrangement.
More Related Videos
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures...
The Carnot Cycle and the Second Law of Thermodynamics
Since the individual steps in a Carnot cycle can be reversed, the entire cycle is, thus, reversible. If a Carnot cycle is reversed, it becomes a Carnot refrigerator. It extracts heat Qc from a cold reservoir at...
Efficiency of The Carnot Cycle
The Carnot Cycle
What could be the theoretical limit to the efficiency of a heat engine? The...
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...