Related Experiment Video
Updated: May 27, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Is cardiopulmonary transit time (CPTT) measured by using dynamic rubidium cardiac PET/CT a predictor for cardiac
Lena C Seige1, Boya Zhang2, Jakob Heimer3
1Department of Nuclear Medicine, Cantonal Hospital Baden, Partner Hospital for Research and Teaching of the Medical Faculty of the University of Zurich, Baden, 5404, Switzerland.
Abstract:
Cardiopulmonary transit time (CPTT) represents the time needed for the circulation of blood from the right to the left ventricle. This parameter can be measured during dynamic acquisition of rubidium ([82Rb]) cardiac PET/CT. To further characterize this marker, we wanted to assess the association between CPTT and parameters of cardiac function derived from echocardiography. Retrospective single center analysis of patients referred to [82Rb]RbCl-PET/CT with rest/stress protocol on an integrated hybrid PET/CT system (Biograph mCT, Siemens Healthineers, Erlangen, Germany) and echocardiography within 100 days. After intravenous injection of 7.5 MBq/kg [82Rb]RbCl dynamic scans with initially 12 × 10 s frames were started. For data analysis a volume of interest (VOI) was drawn in the left and right ventricle using dedicated software. The difference between the peak time for the two time activity curves (TAC) was extracted as CPTT and normalized for heart rate (NCPTT). Associations between NCPTT and echo parameters such as left ventricular ejection fraction (EFEcho) were analyzed using linear regression models. 44 patients (sex: 28 male, 16 female) were enrolled with a time difference between PET and echocardiography of 19.65 ± 23.3 days. 9 patients had a rest CPTT of 0 s, 32 patients 10 s and 3 patients 20 s. The association between EFEcho and NCPTT revealed a significant negative correlation (beta = -0.77; CI: -1.32, -0.22; p = 0.007). Given this association, univariate predictive models for EFEcho were applied. Root mean square error was 6.83% for the EFPET, and 6.0% for NCPTT, which indicates a slightly higher predictive performance for the NCPTT model with a lower error. Pulmonary transit time can be estimated with [82Rb]RbCl-PET/CT, with a high positive association to rest EFEcho. However, smaller time frames than 10 s are needed, for more accurate estimation of cardiac function.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET