Related Experiment Video
Updated: May 27, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Comparison between ligament balancing and measured resection in robot-assisted total knee arthroplasty: a 2-year
Muyang Yu1, Xingdong Yang1, Yiming Xu1
1Department of Orthopedics Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
Purpose:
The two most commonly used techniques for gap balancing in robot-assisted total knee arthroplasty (RA-TKA) are measured resection (MR) and ligament balancing (LB). There are limited studies have reported differences in intraoperative and postoperative outcomes between MR-TKA and LB-TKA in RA-TKA. This study aims to compare the intraoperative and postoperative outcomes of primary RA-TKA between LB and MR techniques.
Methods:
This cohort study utilized prospectively collected data from a single center, spanning from January 2021 to December 2022. We compared the intraoperative procedures and postoperative clinical and imaging results between two groups.
Results:
The LB group had a thinner distal femur cut and a lower usage of thicker polyethylene. Additionally, the LB group exhibited a higher mean femoral component external rotation and greater tibial posterior slope. The rate of soft tissue release and bone recut was lower in the LB group, as was the mean C-reactive protein level.
Conclusion:
In RA-TKA, LB offers advantages in soft tissue protection and bone mass preservation. However, no differences were observed in clinical and radiographic outcomes after a 2-year follow-up.
More Related Videos
05:07Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
09:01Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018