Related Experiment Video
Updated: May 11, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Flexible and rigid guidance in skeletally-anchored maxillary molar distalization: The miniscrew-supported pendulum vs
Poyraz Bulut1, Nilüfer İrem Tunçer1
1Department of Orthodontics, Faculty of Dentistry, Başkent University, Ankara, Turkey.
Introduction:
This study aimed to demonstrate the effects of flexible and rigid appliance designs on maxillary molar distalization.
Methods:
Thirty-six patients with bilateral Class II molar relationships and fully erupted maxillary second molars were included in this study. Half of the patients were treated with the miniscrew-supported pendulum appliance (group 1; aged 16.5 ± 2.1 years) and the other half with the Beneslider appliance (group 2; aged 15.6 ± 1.5 years). Lateral cephalometric radiographs and digital dental models were used to study the dentoalveolar and skeletal changes.
Results:
Distalization time was significantly shorter in group 1 (P = 0.006); however, the first molars in this group displayed considerably more distal tipping (P = 0.030), with lower distalization values (P = 0.022) and rates measured at the crown (P = 0.248), trifurcation (P = 0.410), and root apex levels (P = 0.048). Distalization at the apex level occured only in the Beneslider group, with a root-to-crown distalization ratio of 33.5%. SNB angle decreased (P = 0.010), and ANB (P = 0.010) and SN-GoGn angles (P = 0.010) increased significantly in group 1, all of which were negligible in group 2. Distobuccal rotation of the first molars was significantly higher in group 1 (P = 0.004). The amount of distalization, distal tipping of the maxillary second molars, and appliance success rates were comparable between the groups.
Conclusions:
The Beneslider appliance provided faster maxillary molar distalization with substantially less distal tipping and distobuccal rotation. In contrast, the miniscrew-supported pendulum appliance led to the posterior rotation of the mandible, worsened the sagittal and vertical parameters, and failed to provide distalization at the apex. In summary, our findings indicated that a rigid design for maxillary molar distalization yields more favorable outcomes.
Related Concept Videos
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played by the...
Bending and Torsional Moments
The reaction developed in a structural element when subjected to an external force causes the element to bend. When a structural element bends upwards, it creates compressive normal forces on the top and tensile normal forces on the bottom, resulting in a couple that determines the bending...
Physical Pendulum
When dealing with complicated systems, the mass moment of inertia is an important parameter, as it describes the mass...
Relative Motion Analysis - Acceleration
Stability of structures

