Infrared thermographic assessment of cutaneous temperature changes during labour epidural analgesia initiation: an
A Miglani1, A Borkowska1, B Murphy2
1The Rotunda Hospital, Dublin, Ireland.
Background:
Inadequate labour epidural analgesia within 30 to 45 minutes of insertion is typically considered primary epidural failure and deemed unsuccessful. Early prediction of analgesic success would have clinical benefit, enabling corrective interventions. Sympathectomy accompanying a successful epidural block can cause foot temperature changes. We sought to evaluate the relationship between foot temperature changes and successful epidural, defined as adequate analgesia in 45 minutes of epidural administration. For the purpose of this study, we defined primary epidural failure as inadequate analgesia within 45 minutes of administration.
Methods:
Following ethical committee approval, this observational study was conducted in a tertiary level obstetric centre between January 2021 and March 2024. Patients attending for induction of labour were included: those with labour epidural analgesia comprised the epidural study group, and those without served as a control group. A FlirT540 infrared thermography camera was used to take bilateral foot images every 5 minutes for 30 minutes. Images were taken following epidural administration in the epidural group, and at any convenient time once in established labour in the control group. We studied temperature changes over time in the both groups, and compared the temperature changes in patients with successful and failed epidurals.
Results:
Thirty-eight patients were included in the epidural group and 11 in the control group. Twenty-nine patients (76.3%) had successful analgesia and nine patients (23.7%) had primary epidural failure. Patients with successful analgesia had a statistically significant rise in temperature after 10 minutes. The maximum rate of increase was between 5 and 15 minutes and was 0.5 (0.1)°C per minute on both sides. Primary epidural failure was associated with minimal temperature changes, while all patients who had a 2°C rise in hallux temperature at 10 minutes had successful analgesia.
Conclusions:
Sympathetic blockade associated with a successful analgesic epidural block produces cutaneous temperature elevation at the plantar surface of the hallux. These can be detected within 10 minutes of epidural administration and have a potential role in guiding timely troubleshooting of an unsuccessful epidural.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation