Related Experiment Video
Updated: May 27, 2025

LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation
Published on: January 24, 2025
Effect of light-activation systems associated with whitening pens in the bleaching efficacy and hydrogen peroxide
Laryssa Mylenna Madruga Barbosa1, Gabrielle Gomes Centenaro1, Deisy Cristina Ferreira Cordeiro1
1Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil.
Objective:
To evaluate the bleaching efficacy and hydrogen peroxide (HP) permeability of whitening pens, with and without light-activation systems. Also, pulp temperature and physicochemical properties were assessed, as well as the characterization of the light sources.
Material And Methods:
Ninety premolars were distributed into nine groups (n = 10): untreated, Colgate Optic White Pen ComfortFit LED (CF), Colgate Optic White Pen Express (CX), Equate Teeth Whitening Kit (EW) and Zimba Teeth Whitening Kit (ZW), with and without light-activation. Bleaching efficacy (WID, ΔEab, and ΔE00) was assessed using a digital spectrophotometer. HP permeability (μg/mL) was measured by UV-Vis; initial concentration (%), pH, and pulp temperature variation (ΔT, °C) by titration, pH meter, and T-type thermocouple, respectively. Light characteristics were determined using spectroradiometer and integrating sphere. Statistical analysis included ANOVA, Tukey's, and Dunnett's tests (α = 0.05).
Results:
ZW light device exhibited the highest power and irradiance (p < 0.05). EW and ZW emitted blue light (peak: 456 nm), while CF device emitted violet light (peak: 405 nm). Light-activation did not significantly impact WID or HP permeability (p > 0.05). However, CF and CX showed greater color changes under light, when evaluated by ΔEab/ΔE00 (p < 0.05). All groups showed acidic pH; EW and ZW exhibited the highest HP concentration and permeability (p < 0.05). Pulpal temperature variations were not significant across groups (p > 0.05).
Conclusions:
Light-activation had no significant impact on bleaching efficacy (WID) or HP permeability, regardless of HP concentration or pH.
Clinical Significance:
It is not essential to combine light devices with whitening pens to achieve bleaching efficacy.
More Related Videos
05:57The Synergistic Effect of Visible Light and Gentamycin on Pseudomona aeruginosa Microorganisms
Published on: July 2, 2013
11:04An In-House-Built and Light-Emitting-Diode-Based Photodynamic Therapy Device for Enhancing Verteporfin Cytotoxicity in a 2D Cell Culture Model
Published on: January 13, 2023