Percutaneous retrieval of foreign bodies from the cardiovascular system

Cor Et Vasa
|January 1, 1985
PubMed

Insights

This study shows percutaneous extraction of cardiovascular foreign bodies is safe and effective. A Dormia basket successfully retrieved iatrogenic objects in 10 patients without complications.

Area of Science:

  • Cardiovascular Surgery
  • Interventional Cardiology
  • Medical Device Retrieval

Background:

  • Iatrogenic foreign bodies in the cardiovascular system pose a significant clinical challenge.
  • Transcatheter retrieval is a minimally invasive option for managing these complications.

Purpose of the Study:

  • To evaluate the efficacy and safety of percutaneous retrieval of cardiovascular foreign bodies.
  • To assess the utility of the Dormia basket for this procedure.

Main Methods:

  • Percutaneous retrieval of iatrogenic cardiovascular foreign bodies in 10 patients.
  • Use of a Dormia basket retrieval device in 9 out of 10 cases.
  • Extraction from various cardiovascular locations including the right atrium, pulmonary artery, and iliac vessels.

Main Results:

  • Successful retrieval of foreign bodies in all 10 patients.
  • No procedural complications were reported.
  • The Dormia basket demonstrated high success rates in diverse cardiovascular locations.

Conclusions:

  • Percutaneous extraction is a highly successful and safe treatment for cardiovascular foreign bodies.
  • The Dormia basket is an effective tool for transcatheter retrieval of these objects.
  • This technique is indicated even for non-opaque foreign bodies.