Estimation of Vitreous Chamber Volume Using Axial Length Measurements
Yihong Huang1, Yan Zhang1, Wanzhu Chen1
1Department of Ophthalmology, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China; Department of Ophthalmology, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China and Engineering Research Centre of Assistive Technology for Visual Impairment, Fujian Province University.
Background:
Vitreous chamber volume (VCV) in humans can be accurately measured using magnetic resonance imaging (MRI) combined with ITK-SNAP analysis software. This study explores the relationship between VCV and axial length (AL).
Methods:
This study included 46 healthy individuals, encompassing a total of 92 eyes. Individuals with a history of eye conditions were excluded from the study. AL measurements were obtained using the Lenstar 900 (Haag-Streit, Switzerland). VCV was assessed through MRI using the Ingenia 3.0T system (Philips Medical Systems, Netherlands), with VCV analysis performed using ITK-SNAP analysis software version 3.8.0. The correlation between AL and VCV was evaluated using Pearson linear correlation coefficient, and a logistic regression model was employed to predict VCV.
Results:
The sample consisted of 92 eyes from 46 individuals, including 28 women and 18 men. The average VCV was 6193±1135.9 mm 3 for women and 6324.3±886.7 mm 3 for men. The mean AL for women was 24.70±2.78 mm, while for men it was 24.66±1.70 mm. A significant correlation between AL and VCV was observed ( P <0.001).
Conclusions:
VCV can be accurately estimated through AL measurements, offering a clinically relevant method for assessing VCV.
More Related Videos
07:56Sequential Application of Glass Coverslips to Assess the Compressive Stiffness of the Mouse Lens: Strain and Morphometric Analyses
Published on: May 3, 2016
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Thin-Walled Hollow Shafts
Measurement of Air Content in Concrete
The pressure method,...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving