Related Experiment Video
Updated: May 27, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations
Ronald A Yang1, Kari Hayes1,2, Sarah S Milla1,2
1University of Colorado Anschutz Medical Campus, 13001 E 17th Pl, Aurora, 80045, USA.
Background:
The radiation dose of pediatric general fluoroscopy exams has historically been a topic of concern, with ongoing efforts and significant progress made.
Objective:
The purpose of this study is to evaluate dose performance with a dose monitor program for pediatric general fluoroscopy.
Materials And Methods:
Pediatric general fluoroscopy exams performed between April 1, 2020, and Dec. 31, 2022 were collected and monitored. For each exam, fluoroscopy time, dose-area-product (DAP), reference air kerma (RAK), and patient demographic information were analyzed. RAK, DAP, and fluoroscopy time were tested using Pearson's correlation methods for the three most frequently performed procedures. The influence of patient habitus on dose was studied using linear regression methods. Dose performance among radiologists was compared and so the Wilcoxon signed-rank test between radiologists with ≤ 5 years and > 5 years of experience post fellowship. A significance level of P<0.05 was used to determine statistical significance.
Results:
A total of 12,029 cases were analyzed and the median RAK values range from 0.10 mGy to 1.30 mGy. RAK demonstrated a stronger correlation with DAP (upper gastrointestinal (UGI), R=0.97; P<0.0001) than with fluoroscopy time (UGI, R=0.19; P<0.0001). RAK values were linearly correlated with patient weight (UGI, R=0.49; P<0.0001). A stable trend of median RAK values was observed across the studied time periods. Radiologists with ≤ 5 years' experience showed significantly lower (P<0.0001) RAK than those with > 5 years' experience.
Conclusion:
Variations of pediatric general fluoroscopy dose performance were observed when comparing with other investigations. This study demonstrated that both patient size and operator experience influence radiation output in general fluoroscopy, factors that should be considered for pediatric fluoroscopy procedures.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...