Related Experiment Video
Updated: May 27, 2025

In vitro Assessment of Myocardial Protection following Hypothermia-Preconditioning in a Human Cardiac Myocytes Model
Published on: October 27, 2020
Antifreezing Ultrathin Bioionic Gel-Based Wearable System for Artificial Intelligence-Assisted Arrhythmia Diagnosis
Bingfang Wang1, Ailin Lv1, Haofan Wu1,2
1Research Center for Translational Medicine, Medical Innovation Center and State Key Laboratory of Cardiology, Shanghai East Hospital; The Institute for Biomedical Engineering & Nano Science, Tongji University School of Medicine, Shanghai 200120, China.
Abstract:
Cardiovascular disease (CAD) is a major global public health issue, with mortality rates being significantly impacted by cold temperatures. Stable and reliable electrocardiogram (ECG) monitoring in cold environments is crucial for early detection and treatment of CAD. However, existing skin sensor struggle to balance freeze resistance, breathability, flexibility, conductivity and adhesion at cold temperatures. Here, we introduce a solvent cross-linking strategy and an in situ transfer method to prepare ultrathin bioionic gels, featuring a freezing point below -80 °C and a thickness of only 12.6 μm. The strong and abundant interactions between the ionic liquid solvent and the zwitterionic polymer effectively suppress low-temperature crystallization, forming a toughened and highly adhesive network structure. This network enables the in situ formation of an ultrathin morphology, which can be seamlessly transferred onto various substrates. Furthermore, the solvent-cross-linked network maintains a large interpolymer chain spacing, facilitating rapid ion transport pathways. Even at subzero temperatures, the gel maintains its multifunctionality, demonstrating tissue-like softness (34.6 kPa), high ionic conductivity (10.06 mS cm-1), excellent stretchability (360%), high transparency, robust adhesive strength (175.3 kPa) and interfacial toughness (1146 J m-2). Integrated into a flexible wearable device, the ultrathin gel ensures excellent skin conformity, user comfort, and high signal-to-noise ECG signal acquisition. Leveraging an artificial neural network, the system analyzes bradycardia ECG signals and achieves 96.88% accuracy in arrhythmia detection under cold conditions. This bioionic gel-based system presents a promising solution for early CAD diagnosis and prediction in extreme environments.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022