A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Relationship between difference in endotracheal tube cuff area and airway area with minimum cuff pressure for
Hong-Lei Wu1, Yue-Hong Wu2, Wang-Qin Shen3
1Nursing Department, Affiliated Hospital of Nantong University, Jiangsu, 226001, China.
Abstract:
It is essential for clinicians to select the appropriate endotracheal tube to ensure effective airway management. However, an unmatched endotracheal tube cuff area to the airway area can lead to air or secretion leakage, even at the recommended cuff pressure of 20-30 cmH2O. The present multicenter prospective observational study aimed to determine the relationship between the difference in cuff area and airway area with the minimum cuff pressure to avoid airway leakage. Adult patients who underwent mechanical ventilation were assigned into three groups, with a minimum cuff pressure of < 20, 20-30, and > 30 cmH2O, respectively, in order to have adequate airway sealing. The primary outcome was the difference between the endotracheal tube cuff area and airway area (cuff-airway area difference) that was calculated for the three groups. A total of 284 patients were included, with the mean age of 65.19 (± 14.03) years old. There were 166, 63 and 55 patients who required a minimum cuff pressure of < 20, 20-30 and > 30 cmH2O, respectively. The mean cuff-airway area difference was 236.00 ± 85.26, 149.70 ± 48.34 and - 12.29 ± 113.0 mm2 in the < 20, 20-30, and > 30 cmH2O groups, respectively. In addition, the simple linear regression analysis revealed a negative linear relationship between the cuff-airway area difference and minimum cuff pressure (Y = -0.1266 × X + 46.50, F = 571.40, p < 0.001). It can be concluded that a significant number of patients require a cuff pressure out of the recommended range (< 20 or > 30 mmH2O) to have adequate airway sealing. Patients with a lower cuff-airway area difference require a higher minimum cuff pressure to seal the airway.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...