Related Experiment Video
Updated: May 6, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Clinical and Radiographic Outcomes of Short-Span Fixed Partial Dentures Supported by Two Immediately Placed Implants
Purpose:
To report the implant survival rates and clinical and radiographic outcomes of patients with a short-span fixed partial denture (FPD) supported by two immediately placed implants in the anterior mandible after 5+ years in function.
Materials And Methods:
A total of 100 individuals who had a short-span FPD supported by two immediately placed implants (n = 200) in the lateral incisor region of the mandible for long-term functional life with different loading protocols were chosen for this study. The participants were divided into the following three groups according to loading protocol after implant placement: group 1-immediate implant placement with loading protocol type A; group 2-immediate implant placement with loading protocol type B; and group 3-immediate implant placement with loading protocol type C. Plaque index (PI), bleeding on probing (BOP), probing depth (PD), radiographic crestal bone level (CBL), and implant survival rate were evaluated.
Results:
Three implants failed out of 200. The implants were in function an average of 7 years, and the overall survival rate was 98.5%. The mean PI was 24.86 in group 1, 24.45 in group 2, and 24.77 in group 3. Group 1 had a mean BOP of 29.48, group 2 had a mean BOP of 29.03, and group 3 had a mean BOP of 29.12. Group 1 had a mean PD of 2.03, group 2 had a mean PD of 2.09, and group 3 had a mean PD of 2.11. Additionally, group 1 had a mean radiographic CBL of 1.69 mm, group 2 had 1.56 mm, and group 3 had 1.57 mm. There was no significant difference among the three groups regarding PI, BOP, PD, CBL, or implant survival.
Conclusions:
Within the limitations of this retrospective study, immediate loading for immediately placed dental implants in the mandibular lateral incisor region is a reliable dental rehabilitation option and represents a valid alternative to traditional delayed loading. Immediate implant placement with immediate loading can be advantageous for both patients and physicians. It can save cost and treatment time, and it might be a good alternative for patients who have high esthetic standards for their anterior mandible.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

