Related Experiment Video
Updated: May 5, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Functional Capacity Incorporating Dynamic Ventilation in Systemic Sclerosis: Agreement Analysis Between Performance
Filipe da Silva Reis1, Luis Felipe da Fonseca Reis1, Isabelle da Nobrega Ferreira2
1Rehabilitation Sciences Post-Graduation Programme, Augusto Motta University Centre (UNISUAM), Rio de Janeiro, Brazil.
Abstract:
BackgroundFunctional capacity at submaximal exercise levels has become more popular as an outcome measure in systemic sclerosis (SSc). However, it is necessary to know the ventilatory requirements of the different field tests.ObjectivesTo verify the agreement of the ventilatory dynamics measured at submaximal exercise between the the Glittre-ADL test (TGlittre) and the 6-min walk test (6MWT) and, secondarily, to evaluate the correlations of these measurements with clinical and functional variables in women with SSc (wwSSc).MethodsThis was a cross-sectional study in which 30 wwSSc underwent the 6MWT and TGlittre while hooked to a device reading their ventilatory demand. Physical function was assessed on the Health Assessment Questionnaire Disability Index (HAQ-DI), and lung function was assessed by spirometry.ResultsThe median 6-min walking distance (6MWD) was 344 (282-410) metres, and 25 (83.3%) participants did not reach 80% of the predicted distance. The median TGlittre time was 147 (107-188) seconds, and 18 (60%) participants exceeded 120% of the predicted time. There was agreement between the two tests on the following variables: heart rate (ICC = 0.883, P < 0.0001), breathing reserve (ICC = 0.816, P < 0.0001), peripheral oxygen saturation (ICC = 0.752, P = 0.0009), inspiratory capacity (ICC = 0.690, P < 0.0001), and peak minute ventilation (ICC = 0.433, P = 0.007). There was a weak correlation between 6MWD and TGlittre time (r=-0.353, P = 0.05). 6MWD correlated significantly with the HAQ-DI score (r=-0.606, P = 0.0004) and forced vital capacity (FVC, r= 0.427, P = 0.018). TGlittre time correlated significantly with HAQ-DI (r= 0.440, P = 0.015) and FVC (r=-0.404, P = 0.026).ConclusionIn wwSSc, the 6MWT and TGlittre have almost the same ventilatory requirements, although these patients perform worse in the 6MWT. 6MWD and TGlittre time are weakly correlated. Both 6MWD and TGlittre time are associated with physical function and lung function. Therefore, both tests should be used in clinical practice for the monitoring of these patients as they are complementary.
Related Concept Videos
Lung Capacity
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

