Marc D Rudolph1, Courtney L Sutphen1, Thomas C Register1
1Wake Forest University School of Medicine, 1 Medical Center Boulevard, Winston-Salem, NC 27157-1207, USA.
Introduction:
Studies suggest excellent performance of plasma p-tau217 for detecting amyloid pathology, though studies in more diverse populations are needed to validate previously determined cutpoints.
Methods:
Plasma p-tau217 utility for detecting amyloid pathology (Aβ) via amyloid PET (n=598) and/or cerebrospinal fluid (CSF; n=154) was assessed in a heterogeneous, community-based cohort in the Wake Forest Alzheimer's Disease Research Center (WFADRC). Participants (n=598) were 21% Black; 313 cognitive unimpaired (CU), 214 mild cognitive impairment (MCI), and 64 dementia (DEM); 49% prediabetic, 44% hypertensive; 29% overweight/obese; and 64% with mild-to-moderate kidney disease. Gaussian-mixture models, logistic regression, and receiver operating curve analyses were performed.
Results:
Plasma p-tau217 was associated with elevated Aβ deposition and accurately classified Aβ-positive participants (PET: AUC: 94%-97%, cutpoint≥.338 pg/mL; CSF: AUC = .84, cutpoint≥.307 pg/mL).
Discussion:
Plasma p-tau217 is an accurate indicator of amyloid pathology in a heterogeneous cohort, and superior to other plasma biomarkers assessed. Longitudinal analyses assessing impact of comorbidities on p-tau217 utility for disease progression are underway.