Related Experiment Video
Updated: May 27, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
An International Study of Factors Affecting Variability of Dosimetry Calculations, Part 4: Impact of Fitting
Sara Kurkowska1,2, Julia Brosch-Lenz3, Yuni K Dewaraja4
1Department of Nuclear Medicine, Pomeranian Medical University, Szczecin, Poland.
Abstract:
Individualized radiopharmaceutical therapies guided by patient-specific absorbed dose (AD) assessments using nuclear medicine imaging have the potential to improve both efficacy and safety. Understanding sources of variability in AD calculations is critical for standardization. The Society of Nuclear Medicine and Molecular Imaging Dosimetry Task Force launched the 177Lu Dosimetry Challenge to evaluate variability across steps within the dosimetry workflow. This work aimed to assess the variability in ADs due to different fitting and integration methods. Methods: Anonymized datasets from 2 patients treated with 177Lu-DOTATATE, including serial SPECT/CT scans, segmented organs and lesions, and time-integrated activity maps, were made available online. Participants were invited to perform dosimetry calculations and submit their results using standardized submission spreadsheets. Fitting approaches were categorized, and relative AD variability was analyzed using the quartile coefficient of dispersion and interquartile range. Results: The variability in AD due to the fitting step for patient A's kidneys was less than 1%. In contrast, patient B's kidneys showed higher variability, with values below 10%. Lesions exhibited more variability in fitting than did kidneys, with variability within 25%. Conclusion: The contribution of variability caused by fitting and integration is small for healthy organs. By following recommendations such as selection of appropriate functions, pharmacokinetic modeling, and sanity checks, this variability can be further reduced.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Biological Effects of Radiation
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...