Related Experiment Video
Updated: May 27, 2025

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
The modified effect of mechanical ventilation setting on relationship between fluid balance and hospital mortality
Dawei Zhou1, Yi Lv2, Chao Wang2
1Department of Critical Care Medicine, Beijing Tongren Hospital, Capital Medical University, Beijing, China. zhougreat2005@163.com.
Background:
Fluid supplement may be affected by ventilatory management due to physiological interaction between heart and lung. The aim of the present study was to explore the effects of ventilator strategies on the relationship of fluid balance and hospital mortality for sepsis patients.
Methods:
This was a retrospective cohort study included sepsis patients with invasive mechanical ventilation (MV) over 24 h from Medical Information Mart for Intensive Care (MIMIC) IV database. The accumulative fluid balance increased by 6 h intervals were calculated as fluid intake minus fluid output. The modes (assisted or controlled) and levels (high or low) of positive end-expiratory pressure (PEEP) of MV every 6 h were recorded. The modification effect for modes and levels of PEEP on the relationship of fluid balance and hospital mortality were tested by multivariable regression models, respectively.
Results:
A total of 4466 sepsis patients with invasive MV were included, of which hospital mortality was 26.5%. Fluid balance seemed to have U-shape relationship with hospital mortality. The majority of patients used controlled ventilation at the beginning, and switched to assisted ventilation gradually; however, the PEEP level did not change a lot during the first 24 h. The relationship between fluid balance and hospital mortality was not modified by the ventilator mode; while the PEEP level may modify the relationship.
Conclusions:
For sepsis patients admitted to ICU with invasive MV, the PEEP level, but not the mode of MV, appeared to modify the relationship of fluid balance and hospital mortality. The setting of mechanical ventilation may be an important consideration for fluid therapy.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:

