Wearable Devices for Hemodynamic Assessment in Cardiovascular Disease: A Short Literature Review
Jyotpal Singh1, Chase J Ellingson1,2, Maria Gagarinova1,2
1From the Department of Cardiology, Prairie Vascular Research Inc., Saskatchewan Health Authority, Regina, Saskatchewan, Canada.
Abstract:
Hemodynamic parameters are frequently used in patients with cardiovascular disease to assess cardiac function, monitor disease progression, propose interventions, and determine prognosis. However, they require extensive resources, including specialized equipment and trained personnel, to measure with accuracy and precision. Wearable devices such as wristwatches have been shown to assess heart function, such as heart rate and detection of irregular heart rhythms. These wearable devices have also evolved to measure hemodynamic variables in a noninvasive, dynamic, and rapid manner. However, there is limited research on the accuracy of these wearables for hemodynamic function. This review assesses wearable devices and their utility compared with a clinical reference standard for hemodynamic assessment and highlights the strengths and weaknesses of such devices. Limited studies have found that wearable devices can demonstrate strong correlations when assessing cardiac output, stroke volume, systolic blood pressure and timing intervals, and pre-ejection period. Reproducibility studies in similar clinical conditions are needed, and many of the wearable devices have not received FDA/Health Canada approval, restricting their clinical use. Our review summarizes the current research landscape of wearable devices and hemodynamic assessment and proposes a framework for future research applications.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias