Abstract:
Nonaqueous electroanalytical experiments require a stable and mechanically robust reference electrode (RE). The primary role of an RE is to maintain constant cell potential. Ag/Ag+ and Ag/AgCl are the most widely used REs in nonaqueous electrochemistry due to their robustness, but the disadvantages of chemical and ionic contamination and potential drifts from nonspecific Ag+ activity have caused a shift toward polymer back contact-based solid-state reference electrodes (SSREs). Most polymer-based nonaqueous REs, however, suffer from a lack of structural integrity, exhibit potential drifting, and have ill-defined potential. In this work, a self-doped poly(3,4-ethylenedioxythiophene) and poly(3,4-ethylenedioxythiophene) sulfonated or PEDOT/PEDOT-S (S = sulfonated) polymer-based SSRE was fabricated with high mechanical durability and chemical stability. An unbound sulfonate anion in the EDOT-S polymer backbone of this SSRE increases chemical and mechanical stability. PEDOT/PEDOT-S electrodeposited stainless-steel wires with a commercial polytetrafluoroethylene (PTFE) coating have been fabricated and further optimized with an inner filling of 0.1 M TBAPF6/acetonitrile solution. A potential drift of 2.65 μV/h for the SSRE without an inner filling solution and 1.72 μV/h for the SSRE with it (n = 3) vs Fc/Fc+ were achieved after testing for 14 days. Mechanical bending and twisting of the SSRE preserved the polymer coating, RE function, and mechanical stability. The SSRE with the inner filling solution has been successfully used in nonaqueous electroanalytical and electrolysis applications. The SSRE can be reused after storing without a supporting nonaqueous solution, allowing for the possibility of prolonged dry storage and easy shipping.
More Related Videos
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Membrane Electrodes
Potentiometry: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...