Related Experiment Video
Updated: May 26, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
An automated approach for assessing pressure thresholds on the side of the head
Yujia Du1, Kexiang Liu1, Yuxin Ju1
1School of Design, Hunan University, 410012, Changsha, China.
Abstract:
The aim of this study is to devise strategies for alleviating pressure discomfort associated with glasses-type wearables by examining pressure sensitivity at precise landmarks on the side of the head. A total of 197 healthy participants engaged in an experiment where pressure was applied using an automated force measuring system. Tactile threshold (TT), pressure discomfort threshold (PDT), maximum pressure tolerance (MPT), and pain pressure threshold (PPT) were gauged at 16 locations on the side of the head for each participant. The use of a series of grid-type templates facilitated the localization of landmarks based on individual head shapes and sizes. Notably, the area behind the ears exhibited higher pressure thresholds, while regions where temples sit horizontally were more sensitive to pressure. Gender differences were observed at specific locations, whereas age (<45 years old) and BMI did not exhibit any significant correlation with pressure thresholds. This research introduces an automated methodology for assessing pressure sensitivity through a high-density landmark map on the side of the head. The outcomes have significant implications for the ergonomic design of head-worn products, particularly for glasses-type wearables.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

