Background:
Hand and finger injuries are a common presenting complaint to the emergency department (ED) and are associated with significant morbidity. Neurologic evaluation of these injuries is a crucial component of the patient assessment and can be done via a variety of testing methods.
Discussion:
Although most taught and cited in the ED literature, the two-point discrimination test for sensation has several drawbacks, including limited reproducibility and reliability. Although often utilized by hand surgical specialists, the Semmes-Weinstein monofilament test and the Weinstein Enhanced Sensory Test are not practical for the emergency physician due to the need for specialized equipment and frequent calibration. The Ten Test, a relatively new sensory evaluation method, has been shown to be reliable, reproducible, and pragmatic in varying types of clinical environments.
Conclusion:
The Ten Test is a pragmatic alternative method of evaluation to two-point that is utilized by specialists in hand surgery and injuries. The emergency physician should consider adding the Ten Test to their evaluation and reporting of hand and finger injuries in the ED.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...