Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: Identifying reliable biomarkers
Kajsa Tunedal1, Tino Ebbers2, Gunnar Cedersund3
1Department of Biomedical Engineering, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Abstract:
Cardiovascular digital twins and mechanistic models can be used to obtain new biomarkers from patient-specific hemodynamic data. However, such model-derived biomarkers are only clinically relevant if the uncertainty of the biomarkers is smaller than the variation between timepoints/patients. Unfortunately, this uncertainty is challenging to calculate, as the uncertainty of the underlying hemodynamic data is largely unknown and has several sources that are not additive or normally distributed. This violates normality assumptions of current methods; implying that also biomarkers have an unknown uncertainty. To remedy these problems, we herein present a method, with attached code, for uncertainty calculation of model-derived biomarkers using non-normal data. First, we estimated all sources of uncertainty, both normal and non-normal, in hemodynamic data used to personalize an existing model; the errors in 4D flow MRI-derived stroke volumes were 5-20 % and the blood pressure errors were 0 ± 8 mmHg. Second, we estimated the resulting model-derived biomarker uncertainty for 100 simulated datasets, sampled from the data distributions, by: 1) combining data uncertainties 2) parameter estimation, 3) profile-likelihood. The true biomarker values were found within a 95 % confidence interval in 98 % (median) of the cases. This shows both that our estimated data uncertainty is reasonable, and that we can use profile-likelihood despite the non-normality. Finally, we demonstrated that e.g. ventricular relaxation rate has a smaller uncertainty (∼10 %) than the variation across a clinical cohort (∼40 %), meaning that these biomarkers have clinical potential. Our results take us one step closer to the usage of model-derived biomarkers for cardiovascular patient characterization.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI