Related Experiment Video
Updated: May 26, 2025

Author Spotlight: An Antimicrobial Fabric Using Nano-Herbal Encapsulation of Essential Oils
Published on: April 7, 2023
Thermophysiological comfort characterization of cut-protective fabric consisting of metallic core-covered yarn
Md Zayedul Hasan1,2, Rochak Rathour1, Apurba Das1
1Department of Textile and Fibre Engineering, Indian Institute of Technology Delhi, India.
Abstract:
Cut-protective clothing has issues such as heavy weight, poor comfort and limited mobility. This study used various combinations of core-covered yarn consisting of stainless steel with high-performance polyethylene (HPPE) and polyester wraps to fabricate comfortable cut-protective fabric. Nine cut-protective fabrics with various areal densities (150, 200, 250 g/m2) were prepared with six-end satin weave using core-covered yarn of three distinct linear densities (15, 10, 8 Ne). These fabric samples were employed to evaluate thermophysiological characteristics including air permeability, dry and evaporative heat resistance, thermal conductivity and absorptivity, and wettability according to the established standards. The cut protection of each sample was measured according to Standard No. EN 13997. The cut protection and comfort of cut-resistant clothing are affected by fabric thickness, weight, thread density and bulk density. Thicker heavier fabrics offer better cut protection and heat resistance, while lower bulk density and thread density provide good comfort and thermal transmission.
More Related Videos
07:48Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
11:09Scalable Solution-processed Fabrication Strategy for High-performance, Flexible, Transparent Electrodes with Embedded Metal Mesh
Published on: June 23, 2017
Related Concept Videos
Theory of Metallic Conduction
In this theory, Newton's second law of motion is used to determine the acceleration of an electron in the presence of an applied electric field. Then, its velocity is expressed via this acceleration.
An electron moves through the crystal, containing positive ions,...
Responses to Heat and Cold Stress
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
PPE Use in Healthcare Settings II: Doffing