Related Experiment Video
Updated: Jun 22, 2026

Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
An Unsupervised Approach to Derive Right Ventricular Pressure-Volume Loop Phenotypes in Pulmonary Hypertension
Nikita Sivakumar1,2, Cindy Zhang1,2, Connie Chang-Chien1
1Institute for Computational Medicine Johns Hopkins University Baltimore Maryland USA.
None:
Although right ventricle (RV) dysfunction drives clinical worsening in pulmonary hypertension (PH), information about RV function has not been well integrated in PH risk assessment. The gold standard for assessing RV function and ventriculo-arterial coupling is the construction of multi-beat pressure-volume (PV) loops. PV loops are technically challenging to acquire and not feasible for routine clinical use. Therefore, we aimed to map standard clinically available measurements to emergent PV loop phenotypes. One hundred and one patients with suspected PH underwent right heart catheterization (RHC) with exercise, multi-beat PV loop measurement, and same-day cardiac magnetic resonance imaging (CMR). We applied unsupervised k-means clustering on 10 PV loop metrics to obtain three patient groups with unique RV functional phenotypes and times to clinical worsening. We integrated RHC and CMR measurements to train a random forest classifier that predicts the PV loop patient group with high discrimination (AUC = 0.93). The most informative variable for PV loop phenotype prediction was exercise mean pulmonary arterial pressure (mPAP). Distinct and clinically meaningful PV loop phenotypes exist that can be predicted using clinically accessible hemodynamic and RV-centric measurements. Exercise mPAP may inform RV pressure-volume relationships.
More Related Videos
07:41Induction and Phenotyping of Acute Right Heart Failure in a Large Animal Model of Chronic Thromboembolic Pulmonary Hypertension
Published on: March 17, 2022
07:56Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Cardiac Catheterization II: Right Heart Catheterization
Mitral Regurgitation I: Introduction