Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Multi-Pass Arrival Time Correction in Cyclic Ion Mobility Mass Spectrometry for Imaging and Shotgun Lipidomics
Pattipong Wisanpitayakorn1,2,3, Narumol Jariyasopit1,2,3, Kassaporn Duangkumpha1,2,3
1Siriraj Center of Research Excellence in Metabolomics and Systems Biology (SiCORE-MSB), Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand.
Abstract:
Direct-infusion mass spectrometry (DI-MS) and mass spectrometry imaging (MSI) are powerful techniques for lipidomics research. However, annotating isomeric and isobaric lipids with these methods is challenging due to the absence of chromatographic separation. Recently, cyclic ion mobility mass spectrometry (cIM-MS) has been proposed to overcome this limitation. However, fluctuations in room conditions can affect ion mobility multipass arrival times, potentially reducing annotation confidence. In this study, we developed a multipass arrival time correction method that proved effective across various dates, room temperatures, ion mobility settings, and laboratories using mixtures of reference standards. We observed slight variations in the linear correction lines between lipid and nonlipid molecules, underscoring the importance of choosing appropriate reference molecules. Based on these results, we demonstrated that an accurate multipass arrival time database can be constructed from corrected t 0 and t p for interlaboratory use and can effectively identify isomeric lipids in MSI using only a single measurement. This approach significantly simplifies the identification process compared to determining multipass collision cross-section, which requires multiple measurements that are both sample- and time-intensive for MSI. Additionally, we validated our multipass drift time correction method in shotgun lipidomics analyses of human and mouse serum samples and observed no matrix effect for the analysis. Despite variations in dates, room temperatures, instruments, and ion mobility settings, our approach reduced the mean drift time differences from over 2% to below 0.2%.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Analyzers: Common Types
High-Resolution Mass Spectrometry (HRMS)