Assessment of Occupational Exposure in Some Radiology Departments in Ghana
K O Akyea-Larbi1,2,3, Gustav Gbeddy2, Edith Amoatey2
1Department of Medical Physics, School of Nuclear and Allied Sciences, University of Ghana, Accra, Ghana.
Introduction:
Medical workers account for about 75% of all workers exposed to ionizing radiation; therefore, occupational radiation protection is still a challenge in clinical practices and, consequently, measures should be put in place to optimize radiation in clinical practice.
Objective:
The aim of this study was to assess the occupational radiation dose for staff in some selected radiology departments in Ghana as a precursor for optimization studies.
Methods:
A total of 68 occupationally exposed workers (OEWs) radiation dose history for 5 facilities have been analyzed. This study is a retrospective study that involves the assessment of the dose records of occupational exposed workers in five radiology departments in the Greater Accra region of Ghana from the Radiation Protection Institute of the Ghana Atomic Energy Commission (GAEC) dose records history. The OEWs included in the study were radiographers/technologists, radiologist, physicians, medical physicists, and nurses. These records were collected and assessed for a period of 5 years (2019-2023). TLDs are worn under the lead aprons to estimate Hp (10) or deep dose and on aprons for Hp (0.07) or skin dose.
Results:
A total of 68 OEWs' dose histories for 5 facilities have been analyzed. It was observed that the average annual effective dose for all workers throughout the study period ranged from 0.29 ± 0.07 mSv to 0.41 ± 0.05 mSv. The variations in the mean annual dose for the OEWs for the facilities in the study could be due to the number of OEWs that were monitored and the type and quantity of equipment at the facility during the year under review.
Conclusion:
The occupational radiation dose for OEWs in some selected radiological departments in Ghana have been evaluated. The facility with the highest number of OEWs recorded relatively higher mean annual effective dose. The annual effective doses were lesser than the yearly occupational dose limit of 20 mSv as recommended by national and international guidelines.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...