The effect of camera side on the VOR gain in video head impulse test
Mingwei Xu1,2,3, Qin Zhang1,2,3, Qiong Wu1,2,3
1Department of Otorhinolaryngology-Head and Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
None:
ObjectiveThis study aims to investigate the effect of camera positioning (left-sided vs right-sided) on the vestibulo-ocular reflex (VOR) gain values of normal subjects during the video head impulse test (vHIT), thereby providing valuable reference data for otology clinical practice.MethodsThirty healthy adults (60 ears) were recruited and examined by vHIT for the three pairs of semicircular canals (SCs). During the examination, we meticulously recorded and compared the VOR gain values in the six canal planes-right lateral (RL), left lateral (LL), right anterior-left posterior (RALP), and left anterior-right posterior (LARP)-with the camera positioned on the left side first, followed by repositioning on the right side. We evaluated instantaneous gain (40 ms, 60 ms, and 80 ms), 0-100 ms median gain, and regression gain in 0-100 ms for all SCs.ResultsFor horizontal canals, higher VOR gain values were recorded when the camera was positioned on the same side as the canal being tested. The gain value in LARP was higher when the camera was on the left side than on the right side, while the gain value in RALP was higher when the camera was on the right side than on the left side.ConclusionThis study underscores the importance of camera positioning on VOR gain values for both lateral and vertical canals during vHIT. To mitigate the effects of these variables, standardization of operational procedures and equipment settings is crucial.
Related Concept Videos
Doppler Effect - I
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...