Background:
Atrial fibrillation, which has increased in prevalence by 33% over the past two decades, affects 59 million people worldwide. It is treated using thermal and nonthermal techniques like radiofrequency, cryoballoon, laser, and pulsed-field ablation (PFA). This meta-analysis is the first to compare PFA with high-power short-duration radiofrequency ablation (HPSD-RFA).
Methods:
We comprehensively searched PubMed, Cochrane Central, and ScienceDirect from inception to August 2024. In Review Manager 5.4.1, we pooled risk ratios (RRs) and weighted mean difference (WMD) along with 95% confidence intervals for dichotomous and continuous outcomes, respectively, and employed a random effects model. Study quality was assessed via the Newcastle-Ottawa Scale, and funnel plots were used to evaluate the risk of publication bias.
Results:
Seven studies with a total of 1538 patients were analyzed in this meta-analysis. PFA was associated with a shorter total procedural time (MD = -36.39 min; 95% CI: [-46.23, -26.55]; p < 0.00001; I2 = 90%), left atrial dwell time (MD = -33.22 min; 95% CI: [-53.21, -13.23]; p = 0.001; I2 = 93%), and a longer fluoroscopy time compared to the HPSD-RFA (MD = 9.06 min; 95% CI: [6.13, 11.99]; p < 0.00001; I2 = 96%). Other outcomes were comparable between the two arms.
Conclusion:
PFA outperforms HPSD ablation in terms of procedural efficiency outcomes except for the total fluoroscopy time. Still, both techniques are comparable regarding safety and arrhythmia control outcomes.
More Related Videos
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias