Related Experiment Video
Updated: May 26, 2025

Author Spotlight: Advancing Biotherapeutic Mass Calculation by Introducing mAbScale, a Python-Based Desktop Application
Published on: June 16, 2023
Multilevel─Intact, Subunits, and Peptides─Characterization of Antibody-Based Therapeutics by a Single-Column LC-MS
Kia-Ngee Low1, Yee-Jiun Kok1, Stephen Tate2
1Bioprocessing Technology Institute (BTI), Agency for Science, Technology and Research (A*STAR), 20 Biopolis Way, #06-01 Centros, Singapore 138668, Singapore.
Abstract:
A comprehensive characterization of biotherapeutics, mandated by regulatory authorities, requires analyses of a protein drug at multiple structure levels. Such multilevel characterization can be performed by mass spectrometry (MS), with established conventional MS-based assays of product quality attributes (PQAs) comprising intact protein and subunit middle-up MS with analytes resolved on a C4 column, and bottom-up peptide mapping with analytes resolved on a C18 column. Recent advances in MS have facilitated the increasing use of middle-down analysis, expanding the qualitative analytical capability of MS for protein characterization. Recent studies using less-retentive reversed-phase LC in bottom-up MS also offer an opportunity for streamlining equipment configuration to a single-column LC-MS setup for multilevel characterization of therapeutic proteins. In this study, we developed a robust middle-down LC-MS method on a ZenoTOF 7600 and evaluated a C4 LC-MS setup for the characterization of NISTmAb, RG7221 bispecific antibody (bsAb), and Fc-fusion etanercept by intact protein, subunit middle-up/down, and bottom-up analyses. Successful multilevel characterization of the analytes using C4 LC-MS was demonstrated; notably, high sequence coverage and comprehensive post-translational modification profiling, including the mapping of all 13 O- and 3 N-glycosylation sites on etanercept in a single run, were obtained by bottom-up C4 LC-MS. This is also the first report on middle-down analysis of the major etanercept TNFR and Fc subunit glycoforms. A streamlined single-column LC-MS setup will enable more robust and efficient MS workflows for PQA assessment and simplify the integration of an LC-MS analyzer as a process analytical technology instrument for biopharma applications.
More Related Videos
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
10:50Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Related Concept Videos
Affinity Chromatography
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...