Related Experiment Video
Updated: May 25, 2025

Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
Patterns of Epidural Patch Distribution: The Influence of Spinal Level, Injection Technique, and Patch
Daniel Montes1, Samantha L Pisani Petrucci1, Debayan Bhaumik1
1From the Department of Radiology, Neuroradiology Section (D.M., S.L.P.P., D.B., N.A., A.L.C.), University of Colorado Anschutz Medical Campus, Aurora, Colorado.
Background And Purpose:
Epidural patching with autologous blood and/or fibrin sealant is a common treatment for spinal CSF leaks, yet the factors influencing patch distribution remain poorly understood. This study aimed to analyze the craniocaudal (CC) and ventral epidural (VE) extent of epidural patch material and investigate the impact of variables such as patch volume (PV), composition, spinal level of injection, and patient habitus on distribution patterns.
Materials And Methods:
This retrospective, cross-sectional cohort study included patients who underwent CT-guided epidural patching from January to September 2024. Inclusion criteria were age ≥18 years, dorsal interlaminar (DI) or transforaminal (TFO) epidural patching by using blood, fibrin, or both, and immediate postpatch imaging capturing the entire patch extent. Patch distribution was assessed for CC and VE spread. Statistical analyses included linear and logistic regression models, with multivariate analyses adjusting for confounders.
Results:
Of 152 patients patched during the study period, 33 met inclusion criteria (mean age 45.4 years; 84.1% women) with 44 spinal levels patched: cervical (6.8%), thoracic (68.2%), and lumbar (25%). Mean PV per needle was 7.2 mL, with a mean CC spread of 4.6 spinal levels. There was a positive relationship between PV and CC spread across all spinal levels (β = 0.29, P = .001). Patches in the cervical region demonstrated the highest CC spread efficiency (0.77 levels per milliliter) compared with thoracic (0.56 levels per milliliter) and lumbar patches (0.47 levels per milliliter; P < .01). DI injections achieved greater CC spread but less VE dispersion than TFO injections (5.0 versus 3.2 levels; P = .02; 58.8% versus 70.0%, P = .52). VE spread occurred in 61.4% of cases and followed a nonlinear pattern along the spine, with an inflection point at T3.
Conclusions:
The distribution of epidural patch material is influenced by spinal level, PV, composition, and injection approach. Cervical patches provide the greatest spread efficiency relative to volume, while DI approaches enhance CC spread but reduce ventral dispersion.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs...
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Local Anesthetics: Pharmacokinetics

