Developing a dynamic combined power quality index for assessing the performance of a nuclear facility

Asmaa M Elsotohy1, Mohammed Hamouda Ali2, Ahmed S Adail3

  • 1Department of Nuclear Safety and Radiological Emergencies, NCRRT, Egyptian Atomic Energy Authority, Cairo, Egypt. Asmaa.sotohy@eaea.org.eg.

Scientific Reports
|February 25, 2025
PubMed

Related Concept Videos

Power in a Three-Phase Circuit01:15

Power in a Three-Phase Circuit

Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
283
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
152
Complex Power01:14

Complex Power

Power engineers have introduced the concept of complex power to determine the cumulative effect of parallel loads. This idea plays a crucial role in power analysis because it encompasses all the details related to the power consumed by a specific load.
Complex power is defined as the multiplication of the voltage and the complex conjugate of the current. The magnitude of this power, known as apparent power, is measured in volt-amperes (VA). Notably, the angle of the complex power equates to the...
357
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
92
Nuclear Power02:36

Nuclear Power

Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
7.6K
Power Factor01:11

Power Factor

The power factor is defined as the ratio of average (or active) power to apparent power, as illustrated by the relation
364