Transformer-based conditional generative transfer learning network for cross domain fault diagnosis under limited
Xiang Li1, Jun Ma2,3, Jiande Wu4
1Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming, 650500, China.
Scientific Reports
|February 25, 2025
Summary
This study introduces a Transformer-based conditional Generative Adversarial Network (TCGAN) to improve data generation quality and diversity for fault diagnosis. The new method enhances cross-domain fault diagnosis performance with higher quality generated data.
Area of Science:
- Artificial Intelligence
- Machine Learning
- Deep Learning
Background:
- Current Generative Adversarial Networks (GANs) struggle to balance data quality and diversity, especially with limited data and varying conditions.
- This limitation hinders effective fault diagnosis, particularly in cross-domain scenarios.
Purpose of the Study:
- To propose a novel Transformer-based conditional GAN transfer learning network (TCGAN) to address the limitations of existing GANs.
- To enhance both the quality and diversity of generated data for improved fault diagnosis.
Main Methods:
- Developed a Transformer-based conditional GAN (TCGAN) generative network incorporating sample label information.
- Established a transfer learning network based on TCGAN.
- Implemented a collaborative 'generation-transfer' training strategy using expectation maximization for parallel parameter updating.
Main Results:
- The proposed TCGAN method demonstrated superior data generation quality compared to TTS-GAN and CorGAN.
- Effectiveness validated on bearing datasets from CWRU and KUST-SY.
- Achieved higher quality generated data, outperforming existing methods.
Conclusions:
- The TCGAN approach offers a significant improvement in generating high-quality and diverse data for fault diagnosis.
- Provides a novel and effective solution for enhancing cross-domain fault diagnosis performance.
- Addresses the critical need for robust data generation in challenging industrial environments.
Related Concept Videos
Differential Relays
95
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
95
Power System Three-Phase Short Circuits
72
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Fault Types
64
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
64
Transformers in Distribution System
98
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
98
Transformers
1.0K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.0K
Bus Impedance Matrix
98
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
98