Related Experiment Video
Updated: Jun 16, 2026

Rapid Antimicrobial Susceptibility Testing by Stimulated Raman Scattering Imaging of Deuterium Incorporation in a Single Bacterium
Published on: February 14, 2022
Agar-Dilution Is Comparable to Broth Dilution for MIC Determination in Streptococcus agalactiae
Edward A R Portal1,2,3, Caitlin Farley1, Teresa Iannetelli1,2
1Division of Infection and Immunity, Department of Medical Microbiology, University Hospital of Wales, Cardiff University, Cardiff CF14 4XN, UK.
Background:
Streptococcus agalactiae (Group B Streptococcus, GBS) is a leading cause of neonatal sepsis in high-income countries. While intrapartum antibiotic screening reduces this risk, increasing resistance to macrolides and lincosamides in Europe since the 1990s has limited therapeutic options for penicillin-allergic patients. Reports of reduced beta-lactam susceptibility in GBS further emphasise the need for robust antimicrobial resistance (AMR) surveillance. However, broth microdilution (BMD) methods are unsuitable for large-scale antimicrobial susceptibility testing (AST).
Objective:
To demonstrate that agar-dilution AST provides equivalent results to broth dilution methods, with superior capacity for high-throughput screening.
Methods:
Agar-dilution and microdilution AST methods were compared using a panel of 24 characterised susceptible and resistant GBS strains for benzylpenicillin, chloramphenicol, clindamycin, erythromycin, gentamicin, levofloxacin, tetracycline, and vancomycin. Minimum inhibitory concentration (MIC) agreements were evaluated, and resistance profile correlations were assessed using Cohen's kappa values.
Results:
Agar-dilution demonstrated >90% agreement with BMD MIC for most antimicrobials, except vancomycin (87.5%), erythromycin (83.33%), and tetracycline (52.78%). Cohen's kappa values indicated strong agreement (0.88-1.00) for resistance determination. Agar-dilution avoided "trailing growth" issues associated with BMD and facilitated easier detection of non-GBS contaminants.
Conclusions:
Agar-dilution is a valid method for high-throughput AMR surveillance of retrospective cohorts (96 isolates per plate) and is critical for identifying emerging GBS resistance trends and informing therapeutic guidelines. However, due to the large number of plates required per antimicrobial, it is impractical for routine clinical diagnostics.
Insights
Agar-dilution testing offers a high-throughput method for antimicrobial resistance surveillance in Group B Streptococcus (GBS). This approach is crucial for tracking emerging resistance trends and guiding treatment, though not for routine diagnostics.
Area of Science:
- Clinical Microbiology
- Infectious Diseases
- Antimicrobial Resistance Surveillance
Background:
- Group B Streptococcus (GBS) causes neonatal sepsis, with rising macrolide/lincosamide resistance limiting options for penicillin-allergic individuals.
- Increasing antimicrobial resistance (AMR) in GBS necessitates robust surveillance methods.
- Current broth microdilution (BMD) methods are not suitable for large-scale antimicrobial susceptibility testing (AST).
Purpose of the Study:
- To validate agar-dilution AST as an alternative to BMD for GBS.
- To assess agar-dilution's capacity for high-throughput screening of GBS antimicrobial susceptibility.
Main Methods:
- Compared agar-dilution and microdilution AST for 24 GBS strains against eight antibiotics.
- Evaluated Minimum Inhibitory Concentration (MIC) agreement and resistance profile correlation using Cohen's kappa.
- Assessed agar-dilution's performance in detecting trailing growth and contaminants.
Main Results:
- Agar-dilution showed >90% MIC agreement with BMD for most tested antimicrobials.
- Strong agreement (kappa 0.88-1.00) was observed for resistance determination.
- Agar-dilution mitigated trailing growth issues and improved contaminant detection compared to BMD.
Conclusions:
- Agar-dilution is a valid, high-throughput method for AMR surveillance in GBS, supporting trend identification and guideline development.
- The method is suitable for analyzing large retrospective cohorts (96 isolates/plate).
- Agar-dilution is impractical for routine clinical diagnostics due to the number of plates required per antimicrobial.
More Related Videos
08:54Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds
Published on: February 14, 2018
11:28A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015
Related Concept Videos
Microbial Growth Measurement: Indirect Methods
Microbial Growth Measurement: Direct Methods