An Autoregressive-Based Motor Current Signature Analysis Approach for Fault Diagnosis of Electric Motor-Driven

Roberto Diversi1, Alice Lenzi1, Nicolò Speciale1

  • 1Department of Electrical, Electronic and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy.

PubMed

Related Concept Videos

Electro-mechanical Systems01:19

Electro-mechanical Systems

Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
908
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
110
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
78
Back EMF01:24

Back EMF

Generators convert mechanical energy into electrical energy, whereas motors convert electrical energy into mechanical energy. A motor works by sending a current through a loop of wire located in a magnetic field. As a result, the magnetic field exerts a torque on the loop. This rotates a shaft, extracting mechanical work from the electrical current sent in initially. When the coil of a motor is turned, magnetic flux changes through the coil, and an emf (consistent with Faraday's law) is...
2.7K
Force On A Current Loop In A Magnetic Field01:17

Force On A Current Loop In A Magnetic Field

Magnetic forces on wires carrying current are most frequently applied in motors. A DC motor is a device that converts electrical energy into mechanical work. In motors, wire loops are enclosed in a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate. The direction of the current is reversed once the loop's surface area is lined up with the magnetic field, causing a constant torque on the loop. During the process,...
3.2K