Related Experiment Video
Updated: Jun 19, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
Comparison of three types of scleral fixation of the intraocular lens
Zeeyoon Byun1, Sungsoon Hwang1, Mingui Kong2
1Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul.
Purpose:
This study aimed to compare the 1-year clinical outcomes of three scleral fixation techniques for intraocular lens (IOL) implantation: ab externo scleral fixation, trocar-cannula-based sutureless fixation ("sutureless fixation"), and four-point scleral fixation.
Methods:
This retrospective study evaluated 77 consecutive eyes treated with scleral fixation of the IOL. The ab externo method utilized conventional sutured techniques, while the trocar-cannula-based sutureless method was adapted from the "Yamane" technique, employing a wide-angle fundus lens to facilitate IOL manipulation in the vitreous cavity. The four-point fixation method involved a double-armed polypropylene suture and two 26-gauge needles to secure the four IOL haptics at four distinct sites. One-way analysis of variance (ANOVA) was used for statistical comparison between the groups.
Results:
The four-point fixation group exhibited superior best-corrected visual acuity compared to the sutureless and ab externo groups at 1 and 3 months postoperatively (P = 0.004 and P = 0.002, respectively), along with significantly less surgically induced astigmatism (P < 0.001). The sutureless group had the shortest operative time, while the ab externo group had the longest (P < 0.001). No instances of IOL iris capture occurred in the four-point group, while three cases (10.0%) were noted in the sutureless group.
Conclusion:
The four-point fixation technique provides significant benefits, including faster visual recovery, enhanced IOL stability, and lower surgically induced astigmatism (SIA) values. The sutureless technique provides the benefit of shorter operative times but does pose a risk of IOL capture in a limited number of cases.
Related Concept Videos
Types of Intermediate Filaments
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...